Pour éviter que le système de chauffage électrique ne prenne feu, il est important d'en comprendre la cause et de prendre des précautions !

Jan 18, 2022

Les raisons de l'incendie du système de chauffage électrique sont multiples, dont la plus importante est l'installation du câble chauffant électrique. Tout le monde devrait connaître la méthode d'installation conventionnelle et avoir vu de nombreux-cas d'installation sur site ou des images de cas en ligne. Voici une brève analyse des points clés de l'installation de câbles chauffants électriques qui provoqueront des incendies.


Causes d'incendie à l'extrémité du câble chauffant électrique :

 1. The end treatment is necessary. Of course, the junction box must also be installed to prevent the end from being damp, which may easily cause short circuit and fire.

 2. Improper handling of the tail end exposes the conductive part of the metal. In winter, there is rain and snow, which will cause leakage and fire.

 3. The wrapped tape should be waterproof. If the quality is not good, the end will be wet, causing leakage and fire.

 4. When installing the terminal junction box, the outer sheath should be stripped off, and the shielding layer should be peeled off.

La boîte de jonction entraînera la mise à la terre du circuit. Lorsque le contact de protection de mise à la terre n'est pas bon, il est facile de générer des étincelles électriques et de provoquer un incendie.

Causes d'incendie au milieu du câble chauffant électrique :

 1. During the installation process of the electric heating cable, there is no finished product protection for the electric heating cable. Stepping on, dragging, pulling, and twisting the electric heating cable will cause deformation and damage to the inner core of the electric heating cable. Generally, the construction site is relatively messy, even if it is tough The fluoroplastic jacket type heating tape can also be easily cut without attention. Under the condition of long-term high-power and high-temperature operation, the damaged core has uneven heating, and the local temperature is too high, causing fire.

 2. The thermal insulation layer has not been waterproofed. In rainy and snowy weather, the thermal insulation layer is infiltrated with water, which makes some lines of the heating cable in a low temperature or humid state and work with a large output power. Excessive current causes internal fire and short circuit, resulting in electric sparks.

 3. The outer sheath of the electric heating belt is damaged, and the charged wire core leaks out, and the wire core causes a short circuit in a humid environment in rainy and snowy weather.


En résumé, voici quelques-unes des raisons de l'incendie du câble chauffant électrique dans le système de chauffage électrique. Pour des raisons de sécurité, veuillez installer et utiliser correctement le câble chauffant électrique.

Les professionnels peuvent contacter des professionnels pour l'installation.